Antenna Systems & Solutions, Inc. is pleased to provide the following specifications for Andrew EWP52S, HELIAX® Super Premium Elliptical Waveguide, designed to operate between 5.925–6.425 GHz. If you have any questions, please do not hesitate to contact us. or send us an email.
| Construction Materials |
| Jacket Material |
Unjacketed |
| Conductor Material |
Corrugated copper |
| |
| Dimensions |
| Cable Volume |
1045.0 L/km | 11.3 ft³/kft |
| Cable Weight |
0.88 kg/m | 0.59 lb/ft |
| Diameter Over Jacket (E Plane) |
57.20 mm | 2.25 in |
| Diameter Over Jacket (H Plane) |
33.30 mm | 1.31 in |
| |
| Electrical Specifications |
| Operating Frequency Band |
5.925 – 6.425 GHz |
| eTE11 Mode Cutoff |
3.650 GHz |
| Group Delay |
126 ns/100 ft @ 6.200 GHz | 413 ns/100 m @ 6.200 GHz |
| |
| Environmental Specifications |
| Installation Temperature |
-40 °C to +60 °C (-40 °F to +140 °F) |
| Operating Temperature |
-55 °C to +85 °C (-67 °F to +185 °F) |
| Storage Temperature |
-70 °C to +85 °C (-94 °F to +185 °F) |
| |
| Mechanical Specifications |
| Maximum Twist |
3.00 °/m | 1.00 °/ft |
| Minimum Bend Radius, Multiple Bends (E Plane) |
305.00 mm | 12.00 in |
| Minimum Bend Radius, Multiple Bends (H Plane) |
810.00 mm | 32.00 in |
| Minimum Bend Radius, Single Bend (E Plane) |
200.00 mm | 8.00 in |
| Minimum Bend Radius, Single Bend (H Plane) |
560.00 mm | 22.00 in |
| |
| Standard Conditions |
| Attenuation, Ambient Temperature |
24 °C | 75 °F |
| Average Power, Ambient Temperature |
40 °C | 104 °F |
| Average Power, Temperature Rise |
42 °C | 76 °F |