APC Smart-UPS XL, 1050 Watts / 1400 VA,Input 120V / Output 120V, Interface Port DB-9 RS-232, Extended runtime model, Rack Height 3 U
| Technical Specifications |
Technical Details |
| Output |
| Output Power Capacity |
1050 Watts / 1400 VA |
 |
| Max Configurable Power |
1050 Watts / 1400 VA |
 |
| Nominal Output Voltage |
120V |
 |
| Output Voltage Distortion |
Less than 5% at full load |
 |
| Output Frequency (sync to mains) |
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal |
 |
| Crest Factor |
up to 5 : 1 |
 |
| Waveform Type |
Sine wave |
 |
| Output Connections |
(6) NEMA 5-15R |
 |
| Input |
| Nominal Input Voltage |
120V |
 |
| Input Frequency |
50/60 Hz +/- 3 Hz (auto sensing) |
 |
| Input Connections |
NEMA 5-15PNEMA 5-15P |
 |
 |
| Cord Length |
6 feet (1.83 meters) |
 |
| Input voltage range for main operations |
92 - 147V |
 |
| Input voltage adjustable range for mains operation |
86 - 154V |
| Batteries & Runtime |
| Battery Type |
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof |
 |
| Typical recharge time |
3 hour(s) |
 |
| Replacement battery cartridge |
RBC25 |
 |
| RBC™ Quantity |
1 |
 |
| Replacement battery cartridge note |
UPS and XL BP use a different RBC. SU24RMXLBP2U = RBC26 |
 |
| Typical Backup Time at Half Load |
23.5 minutes (525 Watts) |
 |
| Typical Backup Time at Full Load |
6.6 minutes (1050 Watts) |
 |
| Runtime Chart |
Smart-UPS XL |
 |
| Extended Run Options |
APC Smart-UPS XL 1400VA RM 3U 120V - Black |
| Communications & Management |
| Interface Port(s) |
DB-9 RS-232 |
 |
| Available SmartSlot™ Interface Quantity |
1 |
 |
| Control panel |
LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : and Overload Indicators,LED status display with On Line : On Battery : Replace Battery and Overload indicators |
 |
| Audible Alarm |
Alarm when on battery : distinctive low battery alarm : configurable delays |
 |
| Emergency Power Off (EPO) |
Optional |
| Surge Protection and Filtering |
| Surge energy rating |
800 Joules |
 |
| Filtering |
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 |
| Physical |
| Maximum Height |
5.12 inches (130 mm) |
 |
| Maximum Width |
17.00 inches (432 mm) |
 |
| Maximum depth |
15.50 inches (394 mm) |
 |
| Rack Height |
3U |
 |
| Net Weight |
70.00 lbs. (31.82 kg) |
 |
| Shipping Weight |
85.00 lbs. (38.64 kg) |
 |
| Shipping Height |
13.62 inches (346 mm) |
 |
| Shipping Width |
23.00 inches (584 mm) |
 |
| Shipping Depth |
20.62 inches (524 mm) |
 |
| Color |
Black |
 |
| Units per Pallet |
12.00 |
| Environmental |
| Operating Environment |
32 - 104 °F (0 - 40 °C) |
 |
| Operating Relative Humidity |
0 - 85% |
 |
| Operating Elevation |
0-10000 feet (0-3000 meters) |
 |
| Storage Temperature |
5 - 113 °F (-15 - 45 °C) |
 |
| Storage Relative Humidity |
0 - 95% |
 |
| Storage Elevation |
0-50000 feet (0-15000 meters) |
 |
| Audible noise at 1 meter from surface of unit |
48 dBA |
 |
| Online Thermal Dissipation |
155.00 BTU/hr |
| Conformance |
| Regulatory Approvals |
BSMI,CSA,UL 1778 |
 |
| Standard Warranty |
2 years repair or replace |
 |
| Equipment protection policy |
Lifetime : $150000 |