APC Smart-UPS, 4000 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, RJ-45 10 Base-T ethernet for web/ SNMP/ Telnet management, SmartSlot, Rack Height 7 U
| Technical Specifications |
Technical Details |
| Output |
| Output Power Capacity |
4000 Watts / 5000 VA |
 |
| Max Configurable Power |
4000 Watts / 5000 VA |
 |
| Nominal Output Voltage |
120V,208V |
 |
| Efficiency at Full Load |
95.00% |
 |
| Output Voltage Distortion |
Less than 5% at full load |
 |
| Output Frequency (sync to mains) |
47 - 53 Hz for 50 Hz nominal,57 - 63 Hz for 60 Hz nominal |
 |
| Crest Factor |
up to 5 : 1 |
 |
| Waveform Type |
Sine wave |
 |
| Output Connections |
(2) NEMA 5-15R |
 |
| (12) NEMA 5-20R |
 |
| (2) NEMA L6-20R |
 |
| (1) NEMA L6-30R |
 |
| Input |
| Nominal Input Voltage |
208V |
 |
| Input Frequency |
50/60 Hz +/- 5 Hz (auto sensing) |
 |
| Input Connections |
NEMA L6-30P |
 |
 |
| Cord Length |
8 feet (2.44 meters) |
 |
| Input voltage range for main operations |
157 - 255V |
 |
| Input voltage adjustable range for mains operation |
151 - 268V |
| Batteries & Runtime |
| Battery Type |
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof |
 |
| Typical recharge time |
3 hour(s) |
 |
| Replacement battery cartridge |
RBC55 |
 |
| RBC™ Quantity |
2 |
 |
| Typical Backup Time at Half Load |
26.7 minutes (2000 Watts) |
 |
| Typical Backup Time at Full Load |
9.4 minutes (4000 Watts) |
 |
| Runtime Chart |
Smart-UPS |
| Communications & Management |
| Interface Port(s) |
DB-9 RS-232,RJ-45 10 Base-T ethernet for web/ SNMP/ Telnet management,SmartSlot |
 |
| Available SmartSlot™ Interface Quantity |
1 |
 |
| Pre-Installed SmartSlot™ Cards |
AP9617 |
 |
| Control panel |
LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : and Overload Indicators |
 |
| Audible Alarm |
Alarm when on battery : distinctive low battery alarm : configurable delays |
 |
| Emergency Power Off (EPO) |
Optional |
| Surge Protection and Filtering |
| Surge energy rating |
1020 Joules |
 |
| Filtering |
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 |
| Physical |
| Maximum Height |
12.25 inches (311 mm) |
 |
| Maximum Width |
19.00 inches (483 mm) |
 |
| Maximum depth |
25.00 inches (635 mm) |
 |
| Rack Height |
7U |
 |
| Net Weight |
320.00 lbs. (145.45 kg) |
 |
| Shipping Weight |
355.00 lbs. (161.36 kg) |
 |
| Shipping Height |
25.00 inches (635 mm) |
 |
| Shipping Width |
24.00 inches (610 mm) |
 |
| Shipping Depth |
30.00 inches (762 mm) |
 |
| Color |
Black |
| Environmental |
| Operating Environment |
32 - 104 °F (0 - 40 °C) |
 |
| Operating Relative Humidity |
0 - 95% |
 |
| Operating Elevation |
0-10000 feet (0-3000 meters) |
 |
| Storage Temperature |
5 - 113 °F (-15 - 45 °C) |
 |
| Storage Relative Humidity |
0 - 95% |
 |
| Storage Elevation |
0-50000 feet (0-15000 meters) |
 |
| Audible noise at 1 meter from surface of unit |
53 dBA |
 |
| Online Thermal Dissipation |
1708.00 BTU/hr |
| Conformance |
| Regulatory Approvals |
CSA,FCC Part 15 Class A,UL 1778 |
 |
| Standard Warranty |
2 years repair or replace,optional on-site warranties available,optional extended warranties available |
 |
| Equipment protection policy |
Lifetime : $150000 |